- -$130.00
NextWav 2.5G PoE Series - 16 Ports 2.5G & 6 SFP+ 10G Ports & 500W PoE Power HC16MT6XP UP Series
NextWav 2.5G PoE Series Switches (Model HC16MT6XP_UP Series) are managed POE 2.5Gigabit switches developed for WISP, providing sixteen 2.5Gigabit Ethernet RJ45 ports and six 10Gigabit SFP+ ports.IEEE802.3bt/802.3at/802.3af POE and Passive POE, as well as a maximum rated power of 600W with POE rated power not less than 500W.
There are three types products:
HC16MT6XP_UP_AC support 90~264VAC Power Input
HC16MT6XP_UP_DC support 36~72VDC Power Input
HC16MT6XP_UP_BAT support 9~72VDC Battery Power Input
Due to overwhelming orders, we are trying our best to process all orders the soonest. Please kindly contact us at sales@hyconext.com for estimated delivery date.
1.DC Type support positive or negative 48VDC power supply, the end user must grantee the “+” pole voltage is higher than the “-” pole,and in range of 36VDC~72VDC.
2.For BAT type, the end user must grantee the “+” pole voltage is higher than the “-” pole,and in range of 9VDC~72VDC. DO NOT connect the communication -48VDC power supply(which connect “+” to EARTH)to the PVT products. The PDs which connect POE ”+” to EARTH is NOT ALLOWED to access this BAT Type PVT products. BAT Type mass-produced product support positive or negative power supply. The end user must grantee the “+” pole voltage is higher than the “-” pole,and in range of 9VDC~72VDC.
3.The BAT type PVT products SN is in the range of NYMTBIC00002~ NYMTBIC00050, and MAC is in the range of 54:91:AF:B2:00:97~ 54:91:AF:B2:00:C7
4.The BAT type mass-produced products SN and MAC are out of the range of above PVT products.
5.The relay is in the switch, which support 1.5A@200VDC/140AC or 0.4A@400VDC/280VAC.
6.There are 4 Groups: Ports 1~4, 5~8, 9~12, 13~16. 26V Ports and 52V Ports can’t coexist in the same group. Each group must operate under the same voltage. The software will inform the administrator.
7.The total POE power can’t exceed 500W
8. For some corner cases, At-Risk 24V Non-isolated Passive PoE PDs connected to very early HyconextHC16MT6XPUP BAT/AC Series Switches, may be damaged. Please find details in the attachment.
Security Caution
1.The BAT device has NO ISOLATED POWER SYSTEM INSIDE. The grounding studs on the back panel and racks MUST be connected by a grounding wire to ensure that the device is reliably grounded. The PE/FG of BAT type PVT products are connected to GND of DC input, 52V output, 26V output and 12V output, while the PE/FG of the mass-produced products are not connected to neither positive or negative of DC input, 52V output, 26V output or 12V output.
The BAT type PVT products can only be connected to the battery or the DC power supply which isolated from the Earth. The BAT Type mass-produced product support positive or negative power supply. The end user must grantee the “+” pole voltage is higher than the “-” pole,and in range of 9VDC~72VDC.
Note: The BAT type PVT products SN is in the range of NYMTBIC00002~ NYMTBIC00050, and MAC is in the range of 54:91:AF:B2:00:97~ 54:91:AF:B2:00:C7. The BAT type mass-produced products SN and MAC are out of the range of above PVT products.
2.The DC type devices isolate the input and output, and isolate the 52V output and 12V output. 52V, 26V are not isolated and share the same GND. The grounding studs on the back panel and racks MUST be connected by a grounding wire to ensure that the device is reliably grounded. DC Type support positive or negative 48VDC power supply, the end user must GUARANTEE the “+” pole voltage is higher than the “-” pole,and in range of 36VDC~72VDC.
3.The AC type devices isolate the input and 52V output. 52V, 26V and 12V are not isolated and share the same GND. The grounding studs on the back panel and racks MUST be connected by a grounding wire to ensure that the device is reliably grounded.
4.For the BAT type device, Operator must GUARANTEE the whole system include the PSE and the PDs will not be shorted by the Earth. So DO NOT connect the BAT type PVT products to standard communication -48V power system (which “+” is connected to the Earth and “-“ is connected to -48V). The PDs which connect POE ”+” to the Earth is NOT ALLOWED to access this BAT type PVT products. The PDs which connect POE ”-” to EARTH is NOT ALLOWED to access the mass-produced products that are connected to the communication -48VDC power supply (which connect “+” to EARTH).
5.Must connect the input power cord first, and then turning on the switch between the battery/isolated DC power and the BAT type device. The use of external fuses is encouraged for the BAT type device.
6.RISK OF ELECTRIC SHOCK,DO NOT OPEN THE ENCLOSURE.
7.CAUTION: Disconnect mains before servicing.
8. For some corner cases, At-Risk 24V Non-isolated Passive PoE PDs connected to very early HyconextHC16MT6XPUP BAT/AC Series Switches, may be damaged. Please find details in the attachment.
* Picture is for illustrations purposes only.
Reviews (0)
Global Shipping
Delivering solutions to your country through trusted courier partners.
Warranty
Reliable protection for your peace of mind.
Return & Refund
Hassle-free returns with a customer-first policy.
Certified Reviews
Trusted by professionals, proven by verified feedback.